Thermalview X HR Series

Measurement Method of Skin Temperature

For medical research and product development

Thermography for Medical Research and Skin Temperature Measurement

Type O ・R・ SR

ThermalViewX HR series is a thermography with varieties of functions gradually expanding to meet the needs of those who mainly measure the skin temperature and distribution. High sensitivity, Movie functions, Differential and Statistical Methods and Feature extractions and AI supports your research and interests.

TYPE O​

HR Series TYPE O

Basic software for ensuring reproducibility

Type O, equipped with an offset function, is an application suitable for research and development, enhancing measurement accuracy. It features a function that corrects thermography measurement errors by using a separate reference temperature for calibration.

Main features of TYPE O

An application that enhances measurement accuracy and is suitable for research and developmentnt

Offset function calibrating to a reference temperature

Unlike cooling-type thermographic cameras, standard thermographic cameras are more susceptible to environmental influences, which can cause fluctuations in measurements. The offset function allows you to adjust the measurements to a reference temperature, enhancing temperature accuracy and consistency. It provides compensation for each sensitivity level, allowing offsets to be applied across the entire range rather than just simple adjustments.

画撮影が可能

It is possible to continuously capture still images for the setting number. You can record temperatures in motion like a video, or take multiple shots like a digital camera to choose the best one. The time is recorded to the millisecond for each frame, allowing you to identify exactly when each frame was captured. The data can be converted into a common AVI video file format. Watch the video.
Thermal-view

Easy comparison while displaying in real time

Two-screen display for immediate comparison. Live images can be shown on the left and saved images on the right. This allows you to easily compare images right there.

Simultaneous adjustment of two temperature bars

Each of the two screens has its own temperature bar for adjusting temperature and color, but there is an additional function that allows you to adjust both to the same values. This makes it easy to display the same range on both screens without needing to manually adjust the temperature range for each image.

9 types of compatible cameras

Thermal-camera
ThermalViewX HR32-XA0351
Conpact thermography for skin temperature measurement and thermal analysis
By eliminating unnecessary features, we use a compact, high-performance camera with high sensitivity and high resolution with gigabit Ethernet communication. This standard model, with 80,000 pixels and an NETD of less than 0.05°C, is durable for a wide range of applications.
Thermal-camera
ThermalViewX HR64-XA0650
Conpact thermography for skin temperature measurement and thermal analysis
By eliminating unnecessary features, we use a compact, high-performance camera with high sensitivity and high resolution with gigabit Ethernet communication. Achiving both high spatial resolution with over 320,000 pixels and compact size. This is ideal for applications that require precise temperature measurements of very small areas.
Thermal-camera
ThermalViewX HR46-XA0500
Conpact thermography for skin temperature measurement and thermal analysis
By eliminating unnecessary features, we use a compact, high-performance camera with high sensitivity and high resolution with gigabit Ethernet communication. This next-generation high-sensitivity model is a standard type with NETD of less than 0.035°C, 464×348 resolution with 160,000 pixels, surpassing XA0351.

TYPE R

HR Series TYPE R

Essential analysis software for biological measurements

One of the HR Series models designed for research and development. Equipped with interval thermal imaging measurement, interval CSV output, offset function, and video measurement capabilities

Main features of TYPE R

High-end type with sufficient features for development

Interval video measurement

In cases where you need to capture temperature changes over time, such as during stress tests, full-frame video recordings result in excessively large data. Interval shooting captures images at set intervals, with settings ranging from 1 second to 2 hours.

Interval CSV output

We have integrated the CSV series functionality into the HR series. In some cases, only the temperature data from specified points is sufficient, without needing the thermal image data. You can export temperature data from specified points to a CSV file at intervals ranging from 1 second to 2 hours. This feature is ideal for creating graphs easily in Excel or similar applications.

Offset function to calibrate to the reference temperature

Unlike cooling-type thermographic cameras, standard thermographic cameras are more susceptible to environmental influences, which can cause fluctuations in measurements. The offset function allows you to adjust the measurements to a reference temperature, enhancing temperature accuracy and consistency. It provides compensation for each sensitivity level, allowing offsets to be applied across the entire range rather than just simple adjustments.

Video recording

It is possible to capture a continuous series of still images according to the set number. Each frame’s timestamp is recorded down to the millisecond, allowing you to identify exactly when each frame was taken.

4 types of compatible cameras

Thermal-camera
ThermalViewX HR32-XA0351
Contact required
maintenance
Thermal-camera
サーマルヴューX HR64-XA0650
Contact required
maintenance
Thermal-camera
サーマルヴューX HR46-XA0500
Contact required
maintenance

TYPE SC

HR Series TYPE SC

Specialized for screening

A thermographic camera dedicated to fever detection, equipped with the HR series technology for biological and human applications from ThermalView + A81X, and designed based on principles of public health.

Main features of TYPE SC

Thermographic camera dedicated to screening for fever detection

Thermal image that clarifies temperature differences

ThermalViewX uses color tone curves to respond to the range you want to identify. It reacts near threshold values and visually presents this information clearly to the examiner. Additionally, it is possible to extract distinctive colors using isotherms.
Themography-screening

Various screening variables

To classify as positive or negative during initial screening, it is necessary to set criteria. Simply designating the detection of a specific temperature as positive could lead to excessive false positives or false negatives. Therefore, ThermalViewX offers multiple variables for detection criteria, allowing users to set thresholds and other parameters.

Various methods for notifying testers and subjects

The HR Series Type SC allows for various alert methods, such as emitting warning sounds from PC speakers, changing screen colors, or color-coding using isotherms. To reduce examiner burden and minimize discomfort for subjects, examiners can also customize alert sounds with music files of their choice.

Easy startup and network compatibility

All models in the ThermalView X series offer simple connection and startup for screening. The cameras support IP connectivity, allowing for network connectivity and remote monitoring from distant locations.

3 types of compatible cameras

Thermal-camera
ThermalViewX HR32-SCA0351
Fever detection screening
A thermography dedicated to fever detection, equipped with the HR series technology for biological and human applications from ThermalViewX, and designed based on principles of public health. 
Thermal-camera
ThermalViewX HR64-SCA0650
Fever detection screening
Fever detection screening
Thermal-camera
ThermalViewX HR64-SCA6150
Fever detection screening

maintenance